Made
in 1988 by Swindell Dressler International Company 5100 Casteel
Drive Coraopolis,
Pennsylvania 15108
Number
of cars in kiln
4 Number
of cars outside kiln
1 Kiln
car frame
15’
–8 wide
5’ –
2 long Load
Height from rail level -
9’ Weight
of loaded car
12500 Lb. Track
gage (w/in rail heads )
-
9’ Current
Product --- Toilet
Tanks and Bowls - sanitary ware Power
supply – 230/460 Volt – 3 Ph – 60 Hz Combustion
System Number
of Burners total
24 Top
burners
8 Bottom burners 16Air
Supply Two
20 osi blowers Combustion
air supplied is automatically controlled through the Micromax under P.
I.S.
Loop1 (see operating manual). Fuel
Supply Natural
gas is supplied to the kiln at approximately 2psi and is monitored by a
gas
safety system. An
adjustable port valve regulator in the each zone of gas line downstream
obtains
temperature control Kiln
Pressure Validyne
Draft Range Pressure Transmitter monitors and controls kiln pressure
(see
operating manual). Kiln
Safety Circuit The
safety circuit is designed to shut off the kiln in the event of high
gas
pressure, low gas pressure, low air pressure, or high temperature Send an email for a sketch of this
system.
|